ESW
|
Brand : Exemys
Model : ESW
Type : Networking
Application : Industrial switches with single-mode or multimode optic fiber port (optional) designed for the industrial environment.
Functionality : 4 Port Switches, Half and Full duplex flow control
Ethernet Ports : 2 ports 10 Base T / 100 Base TX, RJ45 connector
Fiber port : 100 Base FX, connector ST or SC (Multimode)100 Base LX10, connector SC (Singlemode).
|
Fiber options: Multimode or Singlemode
Fiber Distance: 2 Km (Multimode) and 10 Km (Singlemode
Wave Lenght: 1300nm
Power : 10~30 VDC
Current : 200mA Max
Dimensions: 100 x 22.5 x 112 mm (H x D x W)
Mounting : DIN rail
Housing:Temperature-resistant industrial case
|
|
MCV2-C485-IA
|
Brand : Exemys
Model : MCV2-C485-IA
Type : Media Converter
Application : Converts a RS232 port to RS485/RS422, for long distance communications and electrically noisy enviroments.
Functionality : RS232 to RS485/422, surge protection in RS422-485 line.
Serial port : RS232/485/422
|
Connection : Half-duplex (2-wires), Full-duplex (4 wires)
Power : 10~30 VDC
Current : 300mA Max
Dimensions: 112.4 x 22.5 x 92.4 mm (HxWxL)
Mounting : DIN rail
Housing:Temperature-resistant industrial case
|
|
MCV2-A485-IA
|
Brand : Exemys
Model : MCV2-A485-IA
Type : Media Converter
Application : RS485 Isolator for communications in environments electrically noisy
Functionality : RS485 to RS485, surge protection for RS485 line.
Serial port : RS485
|
Connection : Half-duplex (2-wires)
Power : 10~30 VDC
Dimensions: 112.4 x 22.5 x 92.4 mm (HxWxL)
Mounting : DIN rail
Housing:Temperature-resistant industrial case
|
|
MCV2-A232-IA
|
Brand : Exemys
Model : MCV2-A232-IA
Type : Media Converter
Application : RS232 Isolator for communications in environments electrically noisy
Functionality : RS232 to RS232 with RTS and CTS lines
|
Serial port : RS232
Power : 10~30 VDC
Dimensions: 112.4 x 22.5 x 92.4 mm (HxWxL)
Mounting : DIN rail
Housing:Temperature-resistant industrial case
|
|
MCV2-A485-CR
|
Brand : Exemys
Model : MCV2-A485-CR
Type : Media Converter
Application : To isolate a port RS485 series, for any instrument of countryside.The electric and electromagnetic fields caused by storms, motors or power electronics, are very often detrimental to the instruments of the field. The module was designed to avoid interference problems or damage, to field instruments that have an RS485 serial port.
|
Functionality : RS485 to RS485 with protection
Serial port : RS485
Power : 10~30 VDC
Dimensions: 112.4 x 22.5 x 92.4 mm (HxWxL)
Mounting : DIN rail
Housing:Temperature-resistant industrial case
|
|
MCV2-C485-CR
|
Brand : Exemys
Model : MCV2-C485-CR
Type : Media Converter
Application : Allows RS232 conversion to RS485, for any field instrument that require further insulation galvanic. Design to avoid interference problems or damage, to field instruments that have an RS232 serial port or RS485.
|
Functionality : RS232 to RS485 with protection
Serial port : RS485
Power : 10~30 VDC
Dimensions: 112.4 x 22.5 x 92.4 mm (HxWxL)
Mounting : DIN rail
Housing:Temperature-resistant industrial case
|
|
MCV1-FO-SER
|
Brand : Exemys
Model : MCV1-FO-SER
Type : Media Converter
Application : Industrial Multimode Fiber Optic to Serial converter, that allows to extend communications up to 2.7 Km and without interferences for electrical noise.
Functionality : Fibre optic to serial (RS232,485,422)
Fiber Optic Port: Transmitter & Receptor
Fiber Optic Connector: ST
Fiber Optic supported: Multimode 50/125 um or 62.5/125 um
|
Maximum Distance: 2.7 Km
Serial port : RS232,485,422
Power : 10~30 VDC
Current : 150mA @ 10V, 75mA @ 30V
Dimensions: 112.4 x 22.5 x 92.4 mm (HxWxL)
Mounting : DIN rail
Housing:Temperature-resistant industrial case
|
|
MCV1-FO-ETH
|
Brand : Exemys
Model : MCV1-FO-ETH
Type : Media Converter
Application : Industrial 10/100 Mbps Ethernet to fiber optics converter. It’s commonly used to interconnect industrial devices PLC, workstations, routers and servers.
Functionality : Fibre optic to Ethernet
Operation Mode: Multimode or Singlemode
Fiber Port: 100 Base FX, ST or SC connector (Multimode) 100 Base LX10, SC connector (Singlemode)
|
Distance: 2 Km on Multimode and 10 Km on Singlemode
Ethernet Port: 10/100 Base TX, RJ45 connector
Protocol: CSMA/CD, Autocross over
Power : 10~30 VDC
Current : 150mA @ 10V, 75mA @ 30V
Dimensions: 112.4 x 22.5 x 92.4 mm (HxWxL)
Mounting : DIN rail
Housing:Temperature-resistant industrial case
|
|
PS-485
|
Brand : Exemys
Model : PS-485
Type : Media Converter/Line Protector
Application : Design to protect electronic equipment, these potentially destructive interferences.Unique with Protection by Overvoltage and Overcurrent in RS485 line. Protects from both surges and overcurrents, and protects agianst alternating currents and also continuous alterations.
Protection against transient peaks: 265Vrms and 20KA-
Protection against AC disturbances: 120 Vrms-
Protection against DC disturbances: 24Vdc
|
ESD (Electrostatic Discharges): IEC 61000-4-2 Level 4 (8KV per contact/15KV per air)
EFT (Fast Electrical Transients): IEC 61000-4-4 Level 3, 1KV, 20A
Current Surge/Lightning: IEC 61000-4-5 Level 4, 4KV, 95A
Serial port : RS485
Power : 10~30 VDC
Dimensions: 112.4 x 22.5 x 92.4 mm (HxWxL)
Mounting : DIN rail
Housing:Temperature-resistant industrial case
|
|
PS-232
|
Brand : Exemys
Model : PS-232
Type : Media Converter/Line Protector
Application : Design to protect electronic equipment, these potentially destructive interferences.Unique with Protection by Overvoltage and Overcurrent in RS232 line. Protects from both surges and overcurrents, and protects agianst alternating currents and also continuous alterations.
Protection against transient peaks: 265Vrms and 20KA-
Protection against AC disturbances: 120 Vrms-
|
ESD (Electrostatic Discharges): IEC 61000-4-2 Level 4 (8KV per contact/15KV per air)
EFT (Fast Electrical Transients): IEC 61000-4-4 Level 3, 1KV, 20A
Current Surge/Lightning: IEC 61000-4-5 Level 4, 4KV, 95A
Serial port : RS232
Power : 10~30 VDC
Mounting : DIN rail
Housing:Temperature-resistant industrial case
|
|