					DataLoop™ LI24 Level Indicator |  
			|  |  
			|  |  
			| 
					Application
					The intrinsically safe loop powered level indicator displays engineering units connected in series with one 4-20 mA continuous level transmitter, and is available with two optional relays and an isolated 4-20 mA repeater. Select this panel mount indicator for use with intrinsically safe two-wire level transmitters. For field mount installation, add a single or two indicator NEMA box. 
					Features
					  
					 LCD main display with secondary unit and bar graph display 
					 Easy configuration via the push button display module 
					 Available with 2 latching relays and isolated 4-20 ma repeater 
					 DIN enclosure with NEMA 4X faceplate and shallow case 
					 Linear, square root and programmable exponent functions 
					 Non-volatile memory with security password protection 
					 Windowed NEMA box accessory for field installations |  
			|  |  
			| 
					Specifications
					
						
							| Display type: | LCD, 5-digit/8-digit bottom |  
							| Display units: | Engineering |  
							| Display output: | -9999 to 99999 (top) / -9999999 to 999999999 (bottom) |  
							| Display height: | 0.7” (17.8mm) top / 0.4” (10.2mm) bottom |  
							| Decimal point: | Floating |  
							| Backlight: | LED / Red for Alarm |  
							| Configuration: | Push button |  
							| Memory: | Non-volatile |  
							| Sensor input: | (1) 4-20 mA transmitter |  
							| Loop power: | 12-30 VDC |  
							| Voltage drop: | 1.5 VDC w/o backlight, 4.5 VDC w/ backlight |  
							| Contact type: | -10_1: N/A; -12_1: (2) SPST relays (latching) |  
							| Contact rating: | -10_1: N/A; -12_1: 1A @ 250 VAC / VDC res. load |  
							| Contact delay: | -10_1: N/A; -12_1: 0-9.999 seconds |  
							| Repeater output: | -1_01: N/A; -1_11: 4-20 mA, 7-30 VDC ext. power required |  
							| Process temp.: | F: -40° to 167° C: -40° to 75°
 |  
							| Ambient temp.: | F: -40° to 185° C: -40° to 85°
 |  
							| Enclosure type: | 1/8 DIN, panel mount |  
							| Enclosure rating: | NEMA 4X (IP65) faceplate |  
							| Enclosure mat'l: | PPE & PS blend |  
							| Classification: | Intrinsically safe |  
							| Compliance: | CE |  
							| Approvals: | UL-C/UL; Class I, Div 1, Groups A, B, C & D T4; Class II, Div 2, Groups A, B, C & D T4; Ex ia IIC T4 (Canada); Class I Zone 0, Zone 1, AEx ia IIC T4 (US); Class I Zone 2, Group IIC T4 (US) |  |  
			|  |  
			|  |  
	  |  |